Effect of wooden floorboards on the vibration of timber floor is a study is aimed at investigating those parameters related to timber flooring that can affect the acceptability of vibration behaviour of a timber floor in a residential building in view of the criteria stated in Eurocode EC5. Source: Timberbiz
The timber floor investigated is made of OSB/3 floorboards and timber joists. The parameters that are investigated in this study are thickness of flooring, floor joist span, joist spacing and connection of floorboards to the joists.
In this context, two cases are considered.
First: the flooring is nailed or screwed to the joists and no composite action or interaction is obtained between joists and floorboards.
Second: the flooring is glued sufficiently to the joists and full interaction is obtained. The result suggests that glued floorboards perform much better with respect to natural frequency, static deflection and peak floor velocity than nailed or screwed floorboards. In almost all cases of glued floorboards, the result complies fully with the Eurocode 5 design vibration requirements. However, as floor lengths increase, the static deflection will increase beyond the allowable limit, especially for relatively thin floor panels and relatively widely spread joists.
For both cases, increasing floorboards thickness and decreasing the joist span by adding more beams can yield even better results to satisfy the requirement of vibration comfort.
You can download the paper here.